5 replacement of the connection cable, 6 building in – Electrolux EGL6382NOX Uživatelská příručka
Stránka 43
tion. Make sure that the ground con-
nection agrees with the standards and
regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
Make sure that you connect the blue neu-
tral cable to the terminal with a letter "N"
on it. Connect the brown (or black) phase
cable to the terminal which has a letter
"L". Keep the phase cable connected at
all times.
8.5 Replacement of the
connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
8.6 Building In
min.
55 mm
min.
650 mm
560 mm
480 mm
min.
450 mm
30 mm
10 mm
3 mm
11 mm
11 mm
A
A
B
A)
supplied seal
B)
supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.7 Possibilities for insertion
Kitchen unit with door
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A)
Removable panel
B)
Space for connections
ENGLISH