Clean the circulating pump – AEG 86720 Uživatelská příručka

Stránka 34

Advertising
background image

Operating instructions

34

When the water is completely drained:

7. Press the end stop firmly back into the emergency drain hose.

8. Push the emergency drain hose back in a little and allow it to snap into

the mounting.

9. Put on the flap and close.

3

The ECO valve does not function when the machine has been fully
emptied. Therefore add approx. 1liter of water before the next wash
(pour in through the detergent drawer).

Clean the circulating pump

1

Warning! Switch off the washing machine and pull the mains plug
before cleaning the circulation pump!

0

1. First perform emergency draining (see above: "Perform Emergency

Drain").

2. Lay a cloth on the floor in front of the circulation pump cover. Some

water may run out.

3. Unscrew the circulation pump cover in an

anti-clockwise direction and remove.

4. Remove foreign body from the pump

housing.

5. Check whether it is possible to turn the

pump impeller. (Jerky pump movement is
normal.) If it is not possible to turn the
impeller, contact customer service.

6. Replace cover (insert stud on the cover

into the guide slot) and tighten in a
clockwise direction.

7. Close emergency drain hose, push in and

fix in place.

8. Close the flap.

Advertising