Electrical connection, En - 15 – Philco PHD 4313 S Uživatelská příručka
Stránka 17
EN - 15
04/2014
Copyright © 2014, Fast ČR, a. s.
Electrical connection
Before connecting the electrical wiring check that:
•
The voltage indicated on the rating label of the appliance (in the rear part) is the same as the voltage in
your power socket.
•
The circuit into which the appliance will be connected must cover the load of the given appliance (see
rating label).
•
The power supply must be grounded in accordance with stipulated valid codes and must be in good condition.
•
The circuit breaker to which the appliance is connected must remain easily accessible.
•
If neither the respective electrical circuit or circuit breaker are available, it is necessary to have one installed
by a qualifi ed electrician before installing and connecting the appliance.
The electrical wiring connection may only be performed by an authorised
service centre or by an electrical technician registered for this purpose!
An incorrect connection will lead to irreparable damage of the device, which may subsequently not be
acknowledged in a warranty claim.
Before connecting, have the voltage in your grid checked to ensure that it conforms to the voltage on the
rating label.
The consumer's connecting voltage (230 V against N) must be verifi ed by a technician using a measuring device.
The length of the power cord must be 1.5 m so that you can connect the device prior to moving it towards the wall.
Protective electrical lines must be performed according valid codes and norms.
The appliance may only be connected to a 230 V ~ 50/60 Hz power grid.
Only connect the appliance to a grounded power socket. Follow the electrical wiring instructions.
The terminal box is located under the rear part of the appliance. Use a screwdriver to open it up.
Power socket
Connections
Power cord diameter
Power cord
Protection fuse
230 V ~ 50/60 Hz
1 phase + N
3x 2.5 mm2
H05 VV-F
H05 RR-F
25 A*
400 V ~ 50/60 Hz
2 phases + N
4x 1.5 mm2
H05 VV-F
H05 RR-F
16 A*
* calculated concurrently with the factor according to the norm EN 60 335-2-6/1990
Connecting the cooktop
Setting the confi guration:
For various types of connections, use brass jumpers located in the cabinet next to the terminals.
Monophase 230V~1P+N
Put a bridge between terminal 1 and 2 and between terminal 3 and 4. Attach the earth to the terminate
“earth”, the neutral N to one of the terminals 3 or 4 and the Phase L to one of the terminals 1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminate “earth”, the neutral N to one of the terminals 3 or 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.
Warning:
Frequent tightening and releasing of screws may damage the eff ectiveness of the tightening of once tightened
screws. We recommend that you handle the screws as little as possible to prevent damaging their threads.
Check that the screws are correctly inserted and tightened.