Part 7: instructions for the technician, Gas connection – Philco PGG 64 Uživatelská příručka
Stránka 14
EN - 12
03/2012
Copyright © 2012, Fast ČR, a. s.
PART 7: INSTRUCTIONS FOR THE TECHNICIAN
CAUTION!
Installation and maintenance may only be performed by qualifi ed personnel in accordance with
valid codes.
The appliance must be disconnected from the power supply before any action is taken. If an
electrical connection is necessary for the performance of work, ensure that all necessary safety
precautions are adhered to.
The side walls of cabinets into which the cooktop is to be installed must not extend past the height
of the workbench.
Do not install the appliance near fl ammable materials such as for example curtains, drapes, etc.
CAUTION!
NEITHER THE MANUFACTURER NOR THE VENDOR TAKE ANY RESPONSIBILITY FOR DAMAGES
ARISING FROM NOT ADHERING TO SAFETY AND INSTALLATION INSTRUCTIONS CONTAINED IN
THIS MANUAL AND NOT ADHERING TO THE CODES VALID IN A GIVEN COUNTRY.
Gas connection
For the gas connection you may choose either rigid connections or a fl exible hose from stainless steel
conforming to valid codes in force.
If you do use a fl exible metal hose, it is important that the hose nowhere touches any moving parts and that it
is not crimped anywhere. The same measures must apply when the cooktop is combined with an oven.
CAUTION!
To ensure correct operation, energy savings and a long lifetime of the appliance it is necessary that
the voltage and pressure of the appliance conforms to the recommended values. The adjustable
connection is attached to a complete ramp using nuts with a G 1/2" thread.
Screw on the parts without using excessive force. Set the connection in the required direction and tighten.
When using fl exible non-metallic hoses
Use a fl exible hose that conforms to valid regulations, if it is possible to perform a complete inspection of the
connection. The hose must be fi rmly attached using clamps in accordance with valid regulations.
Always seal with an end nut and an adjustable connection. Then continue with the gas connection.
The hose must be prepared for use as follows:
•
it must not be longer than 1500 mm.
•
it must be easily accessible for easy inspection of its condition.
•
it must not overheat, the temperature must not exceed room temperature (30°C).
•
in must not be exposed to torsion or tensile forces and it must not be crimped.
•
it must not be in contact with sharp corners or edges.