Part 6: installing the appliance, Safety precautions, Selecting the installation location – Philco PHD 327 Uživatelská příručka
Stránka 14
EN - 12
06/2012
Copyright © 2012, Fast ČR, a. s.
PART 6: INSTALLING THE APPLIANCE
Safety precautions
The appliance MUST be installed in the correct manner from the technical point of view and in accordance
with this installation manual and according to valid local legal codes. The person performing the
installation is responsible for any damages caused by an inadequate installation.
The appliance must only be connected by an authorised technician, who must follow the provisions of the
power company in the installation location.
With respect to protection the appliance is a type I and may only be put into operation if the connection
is properly grounded.
Serious injuries may result if this appliance is not correctly connected to a grounding clamp or is put into
operation without professional installation. The manufacturer is not responsible for incorrect use and
possible damages caused by an incorrect electrical installation.
With respect to electrical protection it is necessary to install type B or C fuses.
If the appliance is not equipped with a plug, then it is necessary to install suitable means for disconnecting
it from the electricity grid in accordance with valid local installation codes.
The power cord must be guided in such a way that it does not touch the hot parts of the cooktop or a stove.
Induction cooktops can only be installed above ovens with ventilation from the same manufacturer.
A refrigerator, dishwasher, stove without ventilation or washing machine may not be installed
under the cooktop.
If the cooktop is installed above a drawer, metal items located inside the drawer space could become
heated to a high temperature by the air circulation coming from the cooktop ventilation, so for this reason
we recommend the use of a partition panel.
For a suitable partition panel you can use a wooden board or purchase adequate accessories.
Any tampering with the appliance, including the replacement of the power cord may only be performed
by an authorised service centre.
ATTENTION:
Neither the manufacturer, importer nor the distributor take any responsibility for damage resulting from
incorrect installation or connection.
Selecting the installation location
Do not place any other appliance in the area up to 65 cm above the appliance.
A range hood must be installed according to the range hood manufacturer's instructions.
The wall in the rear part of the installed cooktop must be made from an infl ammable material.
The length of the power cord must not exceed 2 metres.
Requirements for the workbench
The workbench must be straight and located horizontally. Perform the cut-outs into the built-
in furniture prior to installing the appliance. Remove all splinters and wood shavings otherwise
a malfunction of the electrical components could occur. At the same time ensure that after
performing the cut-out works, the stability of the furniture is not compromised.
The surfaces of the cuts need to be treated so that they are resistant against temperature and moisture
(they could start swelling).
Furniture intended for built-in appliances must be resistant to temperatures of up to 90°C.
The minimum distance from the cut-out to the side wall must be: 40 mm. Do not locate the cooktop
between two side walls. If it is located in such a way, it is necessary to maintain a minimum distance of
200 mm from one of the side walls.