Electrical installation, Panel control, Panel dismounting – Fenix GR panel Uživatelská příručka

Stránka 9: Notice

Advertising
background image

9
















Electrical installation

The panel is equipped with two core cables for 1/N 230 V / 50 Hz. The cable can be fitted with a plug (export markets), removal of the plug
and shortening of the supply lead will not result in loss of warranty

.

Coloured marking of conductors:
Phase - brown,
Neutral (work) conductor - blue.
Feeder cable is connected to the box on the wall, see picture 3. If the supply cord of the appliance is harmed, it must be replaced by pro-
ducer or its service engineer or by similar qualified person to prevent creation of a danger situation.

Panel control

We recommend ensuring the panel control by means of extern space thermostat with switch.
The space thermostat preserves a set temperature of the air in the room.
The panel is also equipped with brake thermostat, which ensures that maximum temperature does not exceed 90 °C.

Panel dismounting

Before loosening of mounting consoles, we disconnect the panel from the mains by means of double pole switch. With use of tools, please,
loosen mounting screws and lift the panel vertically upwards in such a way to loosen consoles out of screws. Next, it is necessary to discon-
nect the feeder cable from the box on the wall.

Notice

Any intervention in the panel can be performed only by a qualified person. Before beginning such a work, the panel must be disconnected
from the current source. Because it is a fragile material, it is necessary to take care during transfer, handling and mounting.

Pic.5

Pic.6

W A1

(mm)

B1

(mm)

C1

(mm)

D1

(mm)

300 460 220 465 220
500 660 220 565 220
700 800 220 565 250
900 800 220 765 300

W A2

(mm)

B2

(mm)

C2

(mm)

D2

(mm)

300 260 220 665 220
500 360 220 865 220
700 360 250 1035 220
900 560 300 1085 220

Advertising