Mounting instructions
Installation, electric connection and first commissioning can by per-
formed only by qualified person.
Distances
Distance of the lower edge of the appliance from the floor must not
be smaller than 15cm. Distance sidelong, e.g. to furniture and up-
wards, must be minimum 15cm. To ensure the right function of the
convector, it is necessary to keep distances mentioned on the
picture 2. In Bathrooms, the convector must be installed in confor-
mity with IEC 364- 7- 701:1984 and may be located in compliance
with the picture 1 in the zones 2 and 3. The convector is gadget
of the class II and is protected against spraying water, protection
IP24.
The convector must not be located directly under mains outlet.
Convector power supply must ensure disconnection in all poles, by
which the distance of open contacts is equal to min.3,5mm. By the
convector Ecoflex G, it does not come after switch- over in position
"0" to the complete disconnection from mains, even if the convector
is switched off through this SW (switch), its input can be 1 to 2W.
Mounting
The convector is wrapped separately in a cardboard cover and is
delivered together with a hang frame. Loosen hang frame from the
convector. Settle the hangings to the wall on the final floor and
mark the holes "A". Bore holes "A" and place wall plugs into them,
see picture 3, 4, position 1. Move the hang frame on the wall so
that the lower holes in the frame cover holes with places wall
plugs, see picture 3, 4, position 2. Bore the upper holes and place
wall plugs into them. Screw the hang frame by means of screws.
The distances L, C und D, see picture 5, change according to the
power of the convector, see chart. C and D define position of the
convector toward the hang frame.
When fixing convector to the supporting construction, you should lift
the convector (to be lighter) until it slips on all clips.