Electrical connection, How to use your appliance – Fenix Ecoflex PREMIER Uživatelská příručka
Stránka 11
4. ELECTRICAL CONNECTION
The electrical installation must be equipped with an Omni
polar circuit breaker with a contact opening gap of at least
3 mm.
The pilot wire (black) must never be connected to the earth (yellow-
green wire).
The electrical connection requires no disassembly. The device
should not be installed under a wall socket.
Respect the polarity:
Phase = Brown
Neutral = Blue / Grey
Pilot Wire = Black
If the power cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid danger.
Installation:
The electrical installation must comply with standards in the country
of installation
Check the tight fit of the wires into the terminals of the wall outlet.
Note: The instructions for programming are sent by the sidecons
signals, measured from the Neutral.
5. HOW TO USE YOUR APPLIANCE
THE SELECTOR MODE ENABLES 5 FONCTIONS :
FONCTIONS
COMFORT
Displays temperature (e.g. 19)
Holds temperature as to thermostat settings.
ECONOMY (SET BACK)
EC
Holds temperature at ~- 3.5°C below comfort temperature.
ANTI- FROST
HG
Holds temperature at ~7°C to avoid frost damage.
STOP
- -
Stops all heating functioning.
PROGRAMMATION
Displays signal of programmer
(function light PROG)
Enables functioning as of programmed orders.
SCREEN DISPLAY
ON/OFF SETTING (Picture here under):
To turn on the heater, put the on/off switch (on the side of the appliance) on
position 1.
For complete shutdown of the heater, turn the switch to position 0.
HEATING ON/OFF:
To start, push MODE button (picture cons) and the will display comfort tempe-
rature (19).
To stop heating, push MODE button until “- - “ (stand- by mode).
Note: Your settings remain in memory; the heater is just on standby.
On/Off Switch