Part 10: error messages, En - 29 – Philco PX 4551 I Uživatelská příručka

Stránka 31

Advertising
background image

EN - 29

07/2011

Copyright © 2011, Fast ČR, a. s.

PART 10: ERROR MESSAGES

Error

messages

Meaning

Reason

Remedy

SR

Failure/Warning

A certain part/parts are

not working or the cooling

process has failed.

Contact a service centre as soon as

possible.

LF

The temperature

of the freezer is

not suffi

ciently

low.

This warning appears

especially after a long

power outage.

1. Do not refreeze food, which has

defrosted, consume in a short time.

2. Set the freezer temperature to the

lowest value or set to the super
freezing mode until this part achieves
the normal operating temperature.

3. Do not insert fresh food until this

failure is repaired.

LC

The temperature

of the

refrigerator is

not suffi

ciently

low.

The ideal refrigerator

temperature is +4°C. If you

note this warning, your

food will be in danger of

spoiling.

1. Set the refrigerator temperature to

the lowest value or set to the super
cooling mode until this part achieves
the normal operating temperature.

2. Open the door as little as possible until

this failure is repaired.

LF and LC

The temperature

is not

suffi

ciently low.

This is a combined LF and

LC failure.

You may note this error message when
the refrigerator is fi rst turned on. The
error message will disappear once normal
temperatures are achieved.

HC

The refrigerator

temperature is

too low.

Due to the very low

temperature the stored

food is starting to freeze.

1. Check that the "Super cooling" mode

has not been activated.

2. Adjust the set cooling temperature

value.

LOPO

Low voltage

If the supply voltage
falls below 170V, the

refrigerator will switch to

steady-state operation.

In this case it is not a defect, this protects
the compressor from damage. This error
message will disappear after the voltage
increases to the required level.

Advertising