Part 10: error messages, En - 29 – Philco PX 4551 I Uživatelská příručka
Stránka 31
EN - 29
07/2011
Copyright © 2011, Fast ČR, a. s.
PART 10: ERROR MESSAGES
Error
messages
Meaning
Reason
Remedy
SR
Failure/Warning
A certain part/parts are
not working or the cooling
process has failed.
Contact a service centre as soon as
possible.
LF
The temperature
of the freezer is
not suffi
ciently
low.
This warning appears
especially after a long
power outage.
1. Do not refreeze food, which has
defrosted, consume in a short time.
2. Set the freezer temperature to the
lowest value or set to the super
freezing mode until this part achieves
the normal operating temperature.
3. Do not insert fresh food until this
failure is repaired.
LC
The temperature
of the
refrigerator is
not suffi
ciently
low.
The ideal refrigerator
temperature is +4°C. If you
note this warning, your
food will be in danger of
spoiling.
1. Set the refrigerator temperature to
the lowest value or set to the super
cooling mode until this part achieves
the normal operating temperature.
2. Open the door as little as possible until
this failure is repaired.
LF and LC
The temperature
is not
suffi
ciently low.
This is a combined LF and
LC failure.
You may note this error message when
the refrigerator is fi rst turned on. The
error message will disappear once normal
temperatures are achieved.
HC
The refrigerator
temperature is
too low.
Due to the very low
temperature the stored
food is starting to freeze.
1. Check that the "Super cooling" mode
has not been activated.
2. Adjust the set cooling temperature
value.
LOPO
Low voltage
If the supply voltage
falls below 170V, the
refrigerator will switch to
steady-state operation.
In this case it is not a defect, this protects
the compressor from damage. This error
message will disappear after the voltage
increases to the required level.